The user pool did not have permission to invoke the lambda
The lambda did not have permission to call the admin auth endpoint
The lambda did not have permission to call the admin get user endpoint
The permissions have been resolved and the lambda now completes successfully, however the user is still not migrated and receives the error An error occurred (NotAuthorizedException) when calling the AdminInitiateAuth operation: Incorrect username or password.
despite the password being known good due to the lambda being able to authenticate with it.
NOTE: A new user pool (v4) was created for the latest pilot (allowing for self-sign-up). When the user originally logged-in and submitted their Form R, they were a member of user pool v3.
...
Resolution
The ideal resolution is us to find and fix the the root cause of the above
NotAuthorizedException
error.
In the meantime, there is a workaround available: sign up again using the same details and all existing data will be restored - which includes their submitted formsResolving the above permissions results in successful lambda completion and migration of a user from prod user pool v3 to v4.
...
Timeline
10:00 Issue flagged-up in TSS channel. Initial checks/ assumptions user hadn’t signed-up yet so email reply sent to user advising them to sign up.
15:35 Reply flagged up in TSS channel. User had already submitted a Form R and was trying to sign in again using the same credentials.
15:35-16:40 Checks to migration process/ user pool config to try and establish the root cause.
16:45 TSS channel msg asking for email reply to be sent advising user on next steps (either wait for fix or try logging in again, sign-up again, or wait for a fix).
15:20 TSS channel msg - email from user saying they have successfully signed in.
...
Root Cause(s)
Not entirely sure of the root cause for
NotAuthorizedException
error Missing permissions (see Detection section above).
NOTE: When testing, the console login error message “incorrect username or password” (NotAuthorizedException
) was not very helpful. (In this case the email and password were correct; the blocker was not having a fake profile in the the prod db which the pre-sign up lambda trigger was looking for). This is unlikely to be an issue for “real” users but might be worth seeing what ways the error msg text can more closely reflect the underlying issue.
...
Action Items
Action Items | Owner |
---|---|
Ticket to making more helpful Cognito error messages | |
Dev checklist for testing some common AWS processes (e.g. migration between user pools) |
...
Lessons Learned
Probably first of its kind of request i.e. user wanting to log in again (via migration between user pools with different configs) to view submitted Form R. This is a good ‘stress test’ !
Reminder not to make too many assumptions (with hindsight, more clues were in the first email from user). Maybe a quick call might of helped to clarify thingshelp to clarify things?
Testing the AWS processes with dummy data etc. is a bit fiddly. Maybe draw-up a checklist of things to remember?