Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Date

 

AuthorsOladimeji Onalaja (Unlicensed)
StatusComplete
Summary


ImpactService Unavailable errors on TIS

Root Cause(s)

Users were getting a 503 "Service Unavailable" error on TIS which would force them to clear their cache in order to be able to reaccess TIS.

Trigger

The number of valid state cookies would exceed the limit which was set to 3 cookies at the time.

Resolution

Updated Open ID Connect from version 2.3.9-1 to 2.3.11-1 as this version includes an option to delete the oldest state cookie once the maximum number of cookies has been reached.

Maximum number of cookies set to 1.

Detection

Alerted by users.

Action Items

Action ItemTypeOwnerIssue
??Restore service

TISNEW-3270 - Getting issue details... STATUS


Timeline

  • August 29, 2019 - TIS Service Unavailable error appears
  • September 2, 2019 - Root cause of errors located
  • September 3. 2019 - Fix implemented
  • No labels